SKU: 53161730751

APO PLV15C-500 15mm 500kPa Male Compression Pressure Limiting Valve

Sale price$22.50 Regular price$25.00
Save 10%

Pay in installments of $6.25 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 26 - Jul 31

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

APO PLV15C-500 15mm 500kPa Male Compression Pressure Limiting ValveOverview The APO PLV15C 500 15mm (1 2") 500kPa PLV pressure limiting valve is commonly used to regulate the supply cold water pressure to hot water services including heat pumps, electric, gas storage and solar water heaters across all mainstream brands in Australia such as Rheem, Vulcan, Rinnal, Dux, Aquamax, Thermann, Apricus and Solahart. The APO PLV pressure limiting valve features the same threads, fitments and similar physical sizes with many

Overview

The APO PLV15C-500 15mm (1/2") 500kPa PLV pressure limiting valve is commonly used to regulate the supply cold water pressure to hot water services including heat pumps, electric, gas storage and solar water heaters across all mainstream brands in Australia such as Rheem, Vulcan, Rinnal, Dux, Aquamax, Thermann, Apricus and Solahart. 

The APO PLV pressure limiting valve features the same threads, fitments and similar physical sizes with many other valve manufacturers such as Reliance, AVG, Tomson, AW, Nefa and Reflex. This makes the APO PLV pressure limiting valve a perfect direct replacement to an existing valve with no plumbing pipe modifications required. When the compression nuts and the copper olives are removed, this PLV pressure limiting valve can be used as male threaded valves.

The PLV pressure limiting valves usually come in 350, 500 and 600kPa ratings under Australian Watermark standard regulations. Each pressure specification is used on specific plumbing applications, depending the pressure rating requirement of the appliances. The PLV pressure limiting valve regulates the inlet water pressure by employing a sliding piston design internally and creates a pressure drop as the water passes through the valve. This piston design is directional and therefore there is an arrow on each pressure limiting valve body indicating the water flow orientation.  

Engineer's Notes

When a PLV pressure limiting valve fails, it is usually caused by the corrosion and debris clogging-up inside the valve body, preventing the piston's sliding actions over its usage life spans. In most cases, the water pressure and flow rate can drop significantly causing an unsatisfying user experience. In less common scenarios, the opposite can also happen and the pressure limiting valve may lose its pressure limiting ability, potentially blowing up appliances with over pressures. 

A PLV pressure limiting valve can only limit the dynamic pressure of the passing inlet water. The valve can not regulate a static pressure increase inside a water heater when the water heats up and expands, where PTR and ECV valves must be used instead for the pressure relief.

The 500kPa is a nominal outlet pressure rating under Australian Watermark Standard testing condition with a set inlet pressure. In real world situations, the actual mains supply water pressure can fluctuate and vary greatly from locations to locations. This presents a challenge for many hot water heater installations, especially when the street's mains pressure is too high. In this scenario, the PLV pressure limiting valve may fail to limit the inlet pressure below the hot water tank's pressure rating requirement. The PTR and ECV valves of the hot water service can leak excessively or even in a continuous stream as consequences. In such situations, pressure reducing valves can be used in the places of the pressure limiting valves to address this problem. 

The compression nuts at the ends of the PLV pressure limiting valve are used to connect to the Australian standard 15mm 1/2"sized copper pipes, which are most common in the residential plumbing. The olives inside bite into the copper pipes to form a water tight seal when the cone nuts are tightened and no plumbing tapes should be used for compression type connections to maximize the biting force. 

When the compression end nuts and olives are removed, the the male threads are exposed underneath. The PLV pressure limiting valve can be used as a threaded valve to screw into fittings and other valves. During all threaded connections, plumbing tapes must be used between the male and female threads. 


Technical Detail

  • Brand: APO
  • Model: PLV15C-500
  • Watermark License Number: WMK26608 
  • Pressure Outlet Rating: 500 kPa
  • Temperature Rating: 80°C
  • Max Inlet Pressure: 2000kPa
  • Flow Rate: 50L/min at max allowable inlet pressure of 2000kPa 
  • Thread Size: 1/2" BSP (15mm) compression ends with copper olives; 1/2" BSP (15mm) male thread when the cone nuts removed
  • Thread Size Physical Measurement: 20.995mm external male thread diameter (refer to the BSP thread sizing chart in the photo gallery); 12.7mm olive internal diameter to suit standard 15mm 1/2"copper pipe
  • Material: DR Brass
  • Intended Use: Domestic Hot Water Services
  • SKU: APO-PLV15C-500

Package Contents

  • APO PLV15C/500 15mm (1/2") 500kPa PLV Pressure Limiting Valve
  • Package Weight: 400g

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 53161730751

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.2 ★★★★★
Based on 9 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
V
Verified Purchase
Violet
Massapequa, US
★★★★★ 5
Gold Star
Size: 1.3 Fl Oz (Pack of 1)
This cream is truly gentle and healing for a compromised skin barrier. I prefer this cream in the winter, when the weather is dry, and after procedures like microneedling or laser. It has never irritated my skin, and does soothe and heal. The La Roche Posay cicalfate cream is also excellent, I think it is slightly less rich, so I prefer that in humidity or the summer.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 2, 2026
N
Verified Purchase
NikkiB
Battle Creek, US
★★★★★ 5
Overpriced but it works.
Size: 1.3 Fl Oz (Pack of 1)
I hate that I love this product. It's stupid expensive. But it's great for broken/damaged/recovering skin. I've used it post microneedling and it is the only thing that soothes, hydrates, and doesn't sting raw, red skin. Great for rashes/hives and allergic reactions too. Luckily a thin layer is often enough to do the trick. so it lasts a long time I wouldn't use for everyday moisture, but when your skin is angry, this stuff works. (Overpriced? Yes. Witchcraft? Maybe. Does it work? Yep.)
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 10, 2025
E
Verified Purchase
English farmhouse
Pawtucket, US
★★★★★ 5
Works wonder
Size: 1.3 Fl Oz (Pack of 1)
Amazing product. The scars from my daughter acne are mostly gone after 1 month. We will purchase again
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 27, 2026
S
Verified Purchase
sandraday
New York, US
★★★★★ 5
Not greasy and no fragrance
Style: Updated Formula
Excellent moisturizer for my sensitive skin.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 26, 2026
A
Verified Purchase
Alice Cooper
Boise, US
★★★★★ 5
Great lotion for very dry skin
Style: Updated Formula
I had a laser done on my face and the products they gave me weren't working. This came highly recommended so I gave it a try. I'm very glad I did! It moisturized my face really well without appearing greasy. I used the rest when my face got dry from winter (in th midwest). Felt very rich and smooth. Medium thickness.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 19, 2025

recommand products